Crane Electronics Ltd | The force in torque management  English  USA  German  French  Spanish  Chinese
JRS - Technical Data PDF Print

Technical Data – Main Unit

  • 0.8KW 0.56 CC/Rev pump with 2 litre valve and 3/8” ports.
  • 3 channel switching unit for torque and angle on 2 and 3 brake units.
  • 2 x 12V, 110Ah Gel batteries with quick release insulated connectors.
  • Integral 11.5A, 24V switch mode battery charger.
  • 24V battery condition indicator.
  • Battery charger isolator to prevent use of equipment whilst in charge cycle.
  • Top mounted control box – comprising 3 torque status lamps; LO, OK and HI. These are coloured amber, green and red respectively.
  • 1 illuminated push button for power on and 1 emergency stop button with key lockout for pump and electronic control system isolation.
  • Optional PC (running Opta Comms) integrated into JRS with swivel flatscreen LCD on top.

Technical Data – Removable Data Collector

  • TorqueStar Opta production unit running JRS specific software.
  • Unit fitted with transducer and serial port extender unit and additional docking connector for charging and communication.
  • Unit designed to be used on board JRS or as a stand-alone device.
  • 16 hour charge with over charge cutout.
  • Nickel metal hydride battery fitted.
  • Battery life of at least 8 hours at 50% duty cycle.
  • Accuracy ± 1% rated maximum transducer capacity.
  • Overload capacity 110% of stated maximum transducer capacity.
  • Zero drift <0.1% of rated transducer maximum capacity.
  • Operating temperature range: +5 to +40 °C.
  • Temperature stability ± 0.1% per degree Celsius.
  • Sealing: IP 40
  • Charge voltage 15V DC, 800 mA.

Lean more