Technical Data – Main Unit
- 0.8KW 0.56 CC/Rev pump with 2 litre valve and 3/8” ports.
- 3 channel switching unit for torque and angle on 2 and 3 brake units.
- 2 x 12V, 110Ah Gel batteries with quick release insulated connectors.
- Integral 11.5A, 24V switch mode battery charger.
- 24V battery condition indicator.
- Battery charger isolator to prevent use of equipment whilst in charge cycle.
- Top mounted control box – comprising 3 torque status lamps; LO, OK and HI. These are coloured amber, green and red respectively.
- 1 illuminated push button for power on and 1 emergency stop button with key lockout for pump and electronic control system isolation.
- Optional PC (running Opta Comms) integrated into JRS with swivel flatscreen LCD on top.
Technical Data – Removable Data Collector
- TorqueStar Opta production unit running JRS specific software.
- Unit fitted with transducer and serial port extender unit and additional docking connector for charging and communication.
- Unit designed to be used on board JRS or as a stand-alone device.
- 16 hour charge with over charge cutout.
- Nickel metal hydride battery fitted.
- Battery life of at least 8 hours at 50% duty cycle.
- Accuracy ± 1% rated maximum transducer capacity.
- Overload capacity 110% of stated maximum transducer capacity.
- Zero drift <0.1% of rated transducer maximum capacity.
- Operating temperature range: +5 to +40 °C.
- Temperature stability ± 0.1% per degree Celsius.
- Sealing: IP 40
- Charge voltage 15V DC, 800 mA.
Lean more
|